OPERATION OF FILTER CLEANING AND DRYING EQUIPMENT

  • PROCEDURE:
  •   PRECAUTIONS:
  • Check the service doors for closed condition before starting the Filter Cleaning equipment.
  • Check the damper position as per standard marking, if not in proper position adjust it.
  • First switch on the Dust extraction system and then switch on the Filter Cleaning equipment.
  • Ensure the drying equipment temperature should not exceed 50ºC.
  • STARTING
  • Ensure that filter cleaning and drying equipment filters are cleaned before starting the operation and record the filter cleaning activity in Annexure-III.
  • Dust extraction system filters will be cleaned whenever the differential filters exceed the limit (specified limit: 20 mm of WC to 150mm of WC) or weekly once, whichever is earlier. Filter cleaning activity will be recorded in Annexure-III.
  • Start the dust extraction system by pressing the start push button. Start the filter cleaning equipment by pressing the start push button. Observe for any abnormal sound or vibrations.
  • Record the activity in the Annexure-I.
  • Clean the filters as per the SOP. 
  • Starts the filter drying equipment by turning selector switches to on position and press the start push button and set the temperature to 50ºC.
  • Dry the filters as per the SOP. 
  • STOPPING
  • Stop the filter cleaning equipment by pressing the stop push button.
  • Record the activity in the Annexure-I.
  • Stop the dust extraction system by pressing the stop push button.
  • Stop the filter drying equipment by pressing stop push button and turn off the selector switch.
  • Record the activity in Annexure-II.
  • REFERENCES:
  •   Not Applicable
  • ANNEXURES: 
ANNEXURE No.TITLE OF ANNEXURE
Annexure-IFilter Cleaning Equipment
Annexure-IIFilter Drying Equipment
Annexure-IIIFilter cleaning Record of Filter cleaning and Drying Equipment
  • DISTRIBUTION:
  • Controlled Copy No. 01                     Head Quality Assurance
  • Controlled Copy No. 02                 Head-Engineering
  • Master Copy                           Quality Assurance Department
  • ABBREVIATIONS:
  • SOP     :      Standard Operating Procedure
  • REVISION HISTORY:
  • CHANGE HISTORY LOG
Revision No.Details of ChangesReason for ChangeEffective Date
00New SOPNot ApplicableTo be written manual

Annexure-I
FILTER CLEANING EQUIPMENT

FILTER CLEANING EQUIPMENT

Annexure-II
FILTER DRYING EQUIPMENT

FILTER DRYING EQUIPMENT

Annexure-III
FILTER CLEANING RECORD OF FILTER CLEANING AND DRYING EQUIPMENT

Share this article
Shareable URL
Prev Post

OPERATION PROCEDURE OF DUST COLLECTOR

Next Post

CALIBRATION OF SHIMADZU HPLC WITH EMPOWER SOFTWARE (MODEL LC-2010CHT)

Leave a Reply

Your email address will not be published. Required fields are marked *

Read next

Discover more from PharmaGuideHub

Subscribe now to keep reading and get access to the full archive.

Continue reading