Your Compass for Pharma Success

OPERATION OF FILTER CLEANING AND DRYING EQUIPMENT

  • PROCEDURE:
  •   PRECAUTIONS:
  • Check the service doors for closed condition before starting the Filter Cleaning equipment.
  • Check the damper position as per standard marking, if not in proper position adjust it.
  • First switch on the Dust extraction system and then switch on the Filter Cleaning equipment.
  • Ensure the drying equipment temperature should not exceed 50ºC.
  • STARTING
  • Ensure that filter cleaning and drying equipment filters are cleaned before starting the operation and record the filter cleaning activity in Annexure-III.
  • Dust extraction system filters will be cleaned whenever the differential filters exceed the limit (specified limit: 20 mm of WC to 150mm of WC) or weekly once, whichever is earlier. Filter cleaning activity will be recorded in Annexure-III.
  • Start the dust extraction system by pressing the start push button. Start the filter cleaning equipment by pressing the start push button. Observe for any abnormal sound or vibrations.
  • Record the activity in the Annexure-I.
  • Clean the filters as per the SOP. 
  • Starts the filter drying equipment by turning selector switches to on position and press the start push button and set the temperature to 50ºC.
  • Dry the filters as per the SOP. 
  • STOPPING
  • Stop the filter cleaning equipment by pressing the stop push button.
  • Record the activity in the Annexure-I.
  • Stop the dust extraction system by pressing the stop push button.
  • Stop the filter drying equipment by pressing stop push button and turn off the selector switch.
  • Record the activity in Annexure-II.
  • REFERENCES:
  •   Not Applicable

Click the link to download word file copy of this document:
https://pharmaguidehub.com/product/operation-of-filter-cleaning-and-drying-equipment/

  • ANNEXURES: 
ANNEXURE No.TITLE OF ANNEXURE
Annexure-IFilter Cleaning Equipment
Annexure-IIFilter Drying Equipment
Annexure-IIIFilter cleaning Record of Filter cleaning and Drying Equipment
  • DISTRIBUTION:
  • Controlled Copy No. 01                     Head Quality Assurance
  • Controlled Copy No. 02                 Head-Engineering
  • Master Copy                           Quality Assurance Department
  • ABBREVIATIONS:
  • SOP     :      Standard Operating Procedure
  • REVISION HISTORY:
  • CHANGE HISTORY LOG
Revision No.Details of ChangesReason for ChangeEffective Date
00New SOPNot ApplicableTo be written manual

Annexure-I
FILTER CLEANING EQUIPMENT

FILTER CLEANING EQUIPMENT

Annexure-II
FILTER DRYING EQUIPMENT

FILTER DRYING EQUIPMENT

Annexure-III
FILTER CLEANING RECORD OF FILTER CLEANING AND DRYING EQUIPMENT

Click the link to download word file copy of this document:
https://pharmaguidehub.com/product/operation-of-filter-cleaning-and-drying-equipment/

Share this article
Shareable URL
Prev Post

OPERATION PROCEDURE OF DUST COLLECTOR

Next Post

CALIBRATION OF SHIMADZU HPLC WITH EMPOWER SOFTWARE (MODEL LC-2010CHT)

Leave a Reply

Your email address will not be published. Required fields are marked *

Read next

Discover more from PharmaGuideHub

Subscribe now to keep reading and get access to the full archive.

Continue reading