  • OBJECTIVE:

To lay down the procedure for cleaning of Glassware used for analytical purposes.

  • SCOPE:

This SOP is applicable for the procedure for cleaning of Glassware used for analytical purposes at {Company /name} {Location}.

  • RESPONSIBILITY:
  • Officer/Executive/Designee Quality Control – Shall be responsible for cleaning of glassware as per SOP.
  • Head/Designee Quality Control – Shall be responsible for ensuring compliance as per SOP.
  • ACCOUNTABILITY:

QA Head shall be Accountable for implementation of SOP.

  • PROCEDURE:
  • After completion of analytical work, keep all the glassware in tray and transfer it into washing area.  
  • General glassware:
  • Wear a rubber apron, safety goggles, and rubber hand gloves.
  • Empty the glassware under the running tap water.
  • Remove any external marking on glassware with solvent.
  • Clean the glassware with suitable nylon brush by using cleaning solution “Teepol solution or Equivalent”.
  • Clean oily and greasy content by using 70% nitric acid solution.
  • Wash the glassware with tap water up to foaming not observed in water by vigorous shaking.
  • Rinse the glassware with purified water.
  • Ensure complete removal of cleaning solution by visual checking.
  • Keep the glassware in inverted position for water drain out from glassware.
  • Finally, the Glassware shall be rinsed with acetone and dried at 40°C.
  • After drying the Glassware shall be removed and stored in their designated places.
  • Ensure cleaning of glassware by visual inspection before use for analysis.
  • Pipette washing:
  • Rinse used pipette with tap water by tubing connected to water line.
  • Rinse it 2-3 times in plastic cylinder having cleaning solution.
  • “Teepol or equivalent”.Rinse it with tap water by tubing connected to water line up to foaming not observed in pipette.
  • Finally rinse the pipette with purified water.
  • Ensure complete removal of cleaning solution from pipette by visual checking.
  • Keep clean pipette in pipette stand for water drain out.
  • Finally, the Glassware shall be rinsed with acetone and dried at 40°C.
  • Transfer clean and dry pipettes in their designated places.
  • Ensure cleaning of pipette by visual inspection before use for analysis.
  • Burette washing:
  • Rinse used burette with tap water by tubing connected to waterline.
  • Rinse it with tap water by tubing connected to waterline up to foaming not observed in Burette.
  • Finally rinse the burette with purified water.
  • Ensure complete removal of cleaning solution from burette by visual checking.
  • Keep clean burette in burette stand for water drain out.
  • Dry it as per the general procedure mentioned above.
  • Transfer clean and dry burette in their designated places.

Click the link to download word file copy of this document:
https://pharmaguidehub.com/product/cleaning-of-glassware-used-in-chemical-and-instrumentation-analysis/

  • REFERENCES:

Not Applicable

  • ANNEXURES: 

Not Applicable

      ENCLOSURES: SOP Training Record.

  • DISTRIBUTION:
  • Controlled Copy No. 01  :          Head Quality Assurance
  • Controlled Copy No. 02  :         Head Quality Control
  • Master Copy                    :          Quality Assurance Department
  • ABBREVIATIONS:
No.:Number
SOP:Standard Operating Procedure
QC:Quality Control
  • REVISION HISTORY:              
CHANGE HISTORY LOG
Revision No.Details of ChangesReason for ChangeEffective Date
00New SOPNot ApplicableTo Be Written Manual

Click the link to download word file copy of this document:
https://pharmaguidehub.com/product/cleaning-of-glassware-used-in-chemical-and-instrumentation-analysis/

Share this article
Shareable URL
Prev Post

CLEANING OF CHEMICAL AND INSTRUMENT LABORATORY

Next Post

CLEANING OF SAMPLING TOOLS

Leave a Reply

Your email address will not be published. Required fields are marked *

Read next

HANDLING OF GLASSWARE

To lay down the procedure for handling of glassware. This SOP is applicable for the procedure for handling of…
Polarimeter: A polarimeter is a scientific instrument used to measure the optical rotation of light, which is…

Discover more from PharmaGuideHub

Subscribe now to keep reading and get access to the full archive.

Continue reading