PREPARATION OF DISINFECTANT SOLUTION

  • PROCEDURE:
  • Wear gloves, nose masks and safety goggles before starting the activity.
  • Transfer the required quantity of original disinfectant in a washed and dried glass beaker.
  • Collect the required quantity of purified water in a sterilized/sanitized container.
  • Mix the original disinfectant with purified water to obtain the specified concentration of disinfectant solution as mentioned in the following table.(For One liter solution )
S. NoName of DisinfectantConcentrationVolume of Disinfectant (ml)Volume of Purified water (ml)
1Microbac forte2 %20980
2Bacillocid special2 %20980
3Korsolex, Rapid2 %20980
4Isopropyl Alcohol70 %700300
  • Arrange the filtration assembly with 0.2 micron membrane filter.
  • Filter the disinfectant by passing through the membrane filter and collect it in a clean, dried and Sterilized/sanitized container.
  • Transfer the required quantity of filtered disinfectant solution in a stainless steel container which has been Sterilized/sanitized previously.
  • Use the filtered disinfectant solution for routine cleaning and sanitization of Microbiology Laboratory on weekly rotation basis.
  • Enter the details of preparation in Disinfectant solution preparation record (Format-I).

Frequency: Once in a week or whenever required.

  • ANNEXURES: 
ANNEXURE NO.TITLE OF ANNEXURE
Annexure-IDisinfectant solution preparation record
  • ABBREVIATIONS:
No.:Number
SOP:Standard Operating Procedure
ml:Milli liter
%:Percentage
QC:Quality Control

Annexure-I
DISINFECTANT SOLUTION PREPARATION RECORD

DISINFECTANT SOLUTION PREPARATION RECORD
Share this article
Shareable URL
Prev Post

OPERATION OF FOGGER

Next Post

OPERATION OF INFRARED THERMO METER MAKE: FLUKE

Leave a Reply

Your email address will not be published. Required fields are marked *

Read next

Discover more from PharmaGuideHub

Subscribe now to keep reading and get access to the full archive.

Continue reading