FUMIGATION IN MICROBIOLOGY TESTING AREA

  • PROCEDURE FOR THE FUMIGATION IN MICRO LAB:
  • Fumigation in a micro lab is a process of using a gas or vapor to decontaminate the lab environment, eliminating microbial growth, spores, and other pathogens. It’s a powerful method for sterilization.
  • The microbiology testing area comprises LAF Room, Cool Zone and Change rooms.
  • Ensure that the LAF rooms shall be free from all the used utensils, culture media plates and Petri plates to be incubated.
  • Switch “OFF” the Laminar air flow units.
  • Switch “OFF” the Air handling Unit.
  • Ensure the safety precautions while doing the fumigation activity.
  • Weigh about 5.0 gm of potassium Permanganate and place in a non-reactive wide mouth plastic container at each location.
  • Perform the fumigation as per the flow direction mentioned below:
  • LAF room
  • Change room-2
  • Cool zone
  • Change room-1

Note: Prior to fumigation activity, wear safety goggles, nose mask and gloves.

  • Subsequently, add about 35 ml of formaldehyde solution to the container containing potassium permanganate.
  • Immediately come out of the respective room.Record the fumigation details in Format-I.
  • Fumigation by using Fogger machine:
  • Prepare the disinfectant solution for fumigation as indicated by manufacturer.
  • Pour the prepared liquid through the funnel on the lid, use hand gloves, goggles and mask.
  • Position the fogger machine in a corner diagonally on stool or table in an angle of 45.
  • Plug in the Fogger machine to ensure gr connection.

Click the link for download word file copy of this document:
https://pharmaguidehub.com/product/fumigation-in-microbiology-testing-area/

    CAUTION: Always ensure “Air filter” is in place before switching on the fogger. Replace filter every 4 months

    • Set the timer to desired minutes of fogging. For 1 lit = 20-25 min (in fixed flow mode)
    • Switch on the fogger machine and leave the clean room and seal it as “Area under Fumigation”.
    • Record the fumigation details in Format-II.

    CAUTION: Fog out 500 ml of plain water after every use, to clean internal tubing’s never tamper with the nozzle. It may lead to permanent damage.

    Note: Ensure all the doors shall be closed.

    • After the completion of fumigation, enter the area with safety goggle, nose mask and gloves.
    • Remove the Plastic containers from the area.
    • If any spillage is observed, handle the spillage as per SOP.
    • Switch “ON” the Air Handling Unit and put the AHU under Exhaust mode for about 2 hrs.Clean the Microbiology testing area as per schedule.
    • Fumigation shall be carried out once in a week.
    • ANNEXURES: 
    ANNEXURE NO.TITLE OF ANNEXURE
    Annexure-IFumigation record
    Annexure-IIFumigation by fogger machine record
    • ABBREVIATIONS:
    No.:Number
    hrs.:hours
    LAF:Laminar Air Flow
    AHU:Air Handling unit
    SOP:Standard Operating Procedure
    QC:Quality Control

    Annexure-I
    FUMIGATION RECORD

    FUMIGATION RECORD

    Annexure-II
    FUMIGATION BY FOGGER MACHINE RECORD

    FUMIGATION BY FOGGER MACHINE RECORD

    Click the link for download word file copy of this document:
    https://pharmaguidehub.com/product/fumigation-in-microbiology-testing-area/

    Share this article
    Shareable URL
    Prev Post

    ENTRY AND EXIT IN TO MICROBIOLOGY TESTING AREA

    Next Post

    PREPARATION OF 10-100 CELLS CULTURE SUSPENSION

    Leave a Reply

    Your email address will not be published. Required fields are marked *

    Read next

    OPERATION OF WATERBATH

    In a microbiology lab , water baths are indispensable for maintaining precise temperatures. They are crucial for…
    OPERATION OF WATERBATH

    Discover more from PharmaGuideHub

    Subscribe now to keep reading and get access to the full archive.

    Continue reading