Your Compass for Pharma Success

ENTRY AND EXIT IN TO MICROBIOLOGY TESTING AREA

  • ENTRY AND EXIT PROCEDURE IN TO MICROBIOLOGY TESTING AREA :
  • A microbiology testing area is a specialized laboratory section designed to analyze and identify microorganisms, such as bacteria, fungi, and viruses.
  • ENTRY TO MICROBIOLOGY TESTING AREA:
  • Entry to microbiology department as per respective SOP.
  • Entry to microbiology testing area is restricted and for concerned persons only.
  • Enter into change room-1.
  • Remove laboratory footwear.
  • Keep it in the designated place provided in the change room-1.
  • Disinfect the hands with 70% IPA solution.

Note: Don’t open the change room-1 door, when change room-2 door is open.

  • Now enter into the Change room -2.
  • Wear the sterile gloves and disinfectant the hands with 70% IPA Solution or suitable disinfectant.
  • Open the garment cubicle and take the sterilized secondary gown and booties.
  • Wear the sterile secondary gown with head cover and booties.
  • Disinfect the gloved hands with 70% IPA Solution or suitable disinfectant.

Note: Personnel working in the Microbiology testing area shall open or shut the doors gently. Shall not perform any fast movements inside the LAF area.

  • Enter into Cool Zone room and take all the necessaries for testing.
  • Enter the LAF Room for further microbiological analysis.
  • Disinfect the gloved hands prior any analysis inside the LAF area.
  • EXIT FROM MICROBIOLOGY TESTING AREA:
  • Enter into the change room, remove the secondary gown with head cover, booties and remove the used gloves and place at designated place.
  • Enter into change room-1, wear laboratory footwear and disinfect the hands with 70 % IPA Solution.
  • Exit from the change room -1.
  • ABBREVIATIONS:
No.:Number
IPA:Isopropyl Alcohol
LAF:Laminar Air Flow
%: Percentage
SOP:Standard Operating Procedure
QC:Quality Control

Click the link for download word file copy of this document:
https://pharmaguidehub.com/product/entry-and-exit-in-to-microbiology-testing-area/

Share this article
Shareable URL
Prev Post

ENTRY AND EXIT INTO MICROBIOLOGY LABORATORY

Next Post

FUMIGATION IN MICROBIOLOGY TESTING AREA

Leave a Reply

Your email address will not be published. Required fields are marked *

Read next

CLEANING OF FOGGER

A fogger usually refers to a fogging machine. This machine disperses a fine mist, or fog, of disinfectant or…

OPERATION OF WATERBATH

In a microbiology lab , water baths are indispensable for maintaining precise temperatures. They are crucial for…
OPERATION OF WATERBATH

Discover more from PharmaGuideHub

Subscribe now to keep reading and get access to the full archive.