Your Compass for Pharma Success

OPERATION OF MICROPIPETTE

  • OBJECTIVE:
  • To lay down the procedure for operation of Micropipette.
  • SCOPE:

This SOP is applicable to the procedure for Operation of Micropipette at {Company Name} {Location}.

  • RESPONSIBILITY:
  • Officer/Executive/Designee Quality Control – Shall be responsible for operation as per SOP.
  • Head/Designee Quality Control – Shall be responsible for ensuring compliance as per SOP.
  • ACCOUNTABILITY:

QA Head shall be Accountable for implementation of SOP.

  • PROCEDURE:
  • Operating Procedure:
  • Set the required volume to be pipetted by using the setting ring.
  • It is advisable to carry out volume setting from the higher down to the lower value. i.e. first go above the desired volume and then return to the lower value.
  • The liquid which is to be aspirated is taken into a suitable vessel.
  • Attach suitable tips to the pipette firmly.
  • Press the control button to the first stop, immerse the pipette tip into the liquid.
  • Allow the control button to slide back slowly.
  • Before removing the tip wait approximately for three seconds, pull the tip out of liquid slowly.
  • Hold the tip in the suitable vessel and press down the control button slowly to the first Stop (measuring stroke) and wait until the liquid stops flowing.
  • Press down the control button to the second stroke (blow out) until the tip is completely empty.Allow the control button to slide back slowly.
  • Tips are rejected by pressing the ejection button on the side of pipette.

NOTE:

  • All the tips should be pre-wetted by aspirating and dispensing liquid two to three times before pipetting.
  • Do not lay down the pipette when a filled pipette tip is attached as this may result in liquid entering the pipette.

Click the link to download word file copy of this document:
https://pharmaguidehub.com/product/operation-of-micropipette/

  • REFERENCES:

Not Applicable

  • ANNEXURES: 

Not Applicable

        ENCLOSURES: SOP Training Record.

  •  DISTRIBUTION:
  • Controlled Copy No. 01  :          Head Quality Assurance
  • Controlled Copy No. 02  :         Head Quality Control
  • Master Copy                    :          Quality Assurance Department
  • ABBREVIATIONS:
No.:Number
SOP:Standard Operating Procedure
QC:Quality Control
  • REVISION HISTORY:             

CHANGE HISTORY LOG

Revision No.Details of ChangesReason for ChangeEffective Date
00New SOPNot ApplicableTo Be Written Manual

Click the link to download word file copy of this document:
https://pharmaguidehub.com/product/operation-of-micropipette/

Share this article
Shareable URL
Prev Post

OPERATION OF CENTRIFUGE Make: REMI

Next Post

OPERATION OF UV CABINET

Leave a Reply

Your email address will not be published. Required fields are marked *

Read next

OPERATION OF UV CABINET

QA Head shall be Accountable for implementation of SOP. Click the link to download word file copy of this…

Discover more from PharmaGuideHub

Subscribe now to keep reading and get access to the full archive.

Continue reading