OBJECTIVE:

To lay down a procedure for establishing guidelines for reporting of analytical values and rounding off the digits.

SCOPE:

This SOP is applicable for the procedure for establishing guidelines for reporting of analytical values and rounding off the digits.

RESPONSIBILITY:

  • Executive/Designee Quality Control: responsible to follow the procedure as per the SOP.
  • Head QC: responsible for ensuring the compliance of SOP.

ACCOUNTABILITY:

QA Head shall be Accountable for implementation of SOP.

PROCEDURE:

After completion of the analysis, the analytical chemist shall calculate the analytical result in the work sheet and compare it with the stated limits in the specification.

The calculated analytical values shall be reported in the worksheets, COAs and raw data sheets as given in the following table:

Methodology for Reporting of Analytical Results:

S.No.TestParameterReporting method
1.Related Substances
No peak detectedNot detected
Unknown Impurity (found below the limit)Disregarding valueBelow         %* (mention limit)
Known Impurity (found below the LOD limit)LODBelow LOD*
 Known Impurity (Found between LOD & LOQ)LOQBelow LOQ*
2.Residual solvents
No peak detectedNot detected
Found below the LOD limitLODBelow LOD*
Found between LOD & LOQLOQBelow LOQ*

At the end of the COA mention the expansion of LOQ, LOD and Disregarding value.

When reporting the results of the Related substances, see the disregarding limits of Unknown impurities and LOD & LOQ limits of known impurities. Do not consider the Unknown impurities which are below the disregarding limit.

If the Known impurity is less than the LOD do not consider for calculation.

If the Impurity value is more than LOD limit and less than the LOQ do not consider for calculating total impurities and individual impurities.

Any Known impurity value more than the LOQ limit shall be considered for calculation of total impurities.

If the calculated value(s) contains more digits in the decimal place than that in the stated limit, The digits after decimal place shall be rounded off as described below.

Rounding off shall be done by considering only one digit in the decimal place to the right of the last place in the limit expression as shown in the illustration below If the digit is smaller than 5, it shall be eliminated and the preceding digit shall remain unchanged.

If the digit is greater than or equal to 5, it shall be eliminated and the preceding digit shall be increased by one.

        Note: Limits are fixed numbers and shall not be rounded off.

        Click the link to download word file copy of this document:
        https://pharmaguidehub.com/product/reporting-of-analytical-values-and-rounding-off-the-digits/

        Methodology for Rounding off of Analytical Values:

        S. No.TestParameterReporting method
        1.Related SubstancesMore than 1.0%One digit after the decimal
        2.Related SubstancesLess than or equal to 1.0% (1.0 % – 0.1%)Two digits after the decimal
        3.Related SubstancesLess than or equal to 0.1% (0.1% – 0.01%)As per LOQ decimal
        4.Related SubstancesLess than 0.01% (0.01% – 0.001%)As per LOQ decimal
        5.DissolutionOne digit after the decimal
        6.Assay in mgAbove 100mg one digit after the decimal and Below that as per specification
        7.Assay in %One digit after the decimal
        8.Content Uniformity in mgAbove 100mg one digit after the decimal and Below that as per specification
        9.Content Uniformity in %One digit after the decimal
        10Water content (By KF) , Particle Size (By Malvern), Viscosity DSC, Melting point and refractive index and Specific optical Rotation etc.Report as per instrument output.

        Illustration of Rounding Numerical Values for comparison with requirements:

        Compendial RequirementUnrounded valueRounded resultsConforms
        Assay limit ³ 98.0%97.96%98.0%Yes
        97.92%97.9%No
        97.95%98.0%Yes
        Assay limit £101.5%101.55%101.6%No
        101.46%101.5%Yes
        101.45%101.5%Yes
        Limit test £ 0.02%0.025%0.03%No
        0.015%0.02%Yes
        0.027%0.03%No
        Limit test £ 3ppm0.00035%0.0004%No
        0.00025%0.0003%Yes
        0.00028%0.0003%Yes

        When the analytical method or test requires quantification, in such cases, the analytical result shall be expressed as observed numerical value.

        When the analytical method or test does not require quantification, in such cases the analytical Result shall be expressed as “Conform” or “does not conform” as the case may be on Certificate of Analysis.

        However, in the work sheet, the actual observation of analysis shall be specified (for Example: Less than 50ppm, colour intensity of sample solution is not more than that of standard Solution “x” or formation of specific colour to the solution or formation of precipitate).

        Analytical values or results for the tests shall be expressed with units as given in Format-I.

        REFERENCES:

        Not Applicable

        ANNEXURES: 

          ANNEXURE NO.TITLE OF ANNEXURE
          Annexure-IDifferent Units of Tests applied in Quality Control

                  ENCLOSURES: SOP Training Record.

          DISTRIBUTION:

          • Controlled Copy No. 01  :          Head Quality Assurance
          • Controlled Copy No. 02  :         Head Quality Control
          • Master Copy                    :          Quality Assurance Department

          ABBREVIATIONS:

          No.:Number
          LOD:Limit of Detection
          LOQ:Limit of Quantification
          COA:Certificate of Analysis
          SOP:Standard Operating Procedure
          QC:Quality Control

          REVISION HISTORY:             

          CHANGE HISTORY LOG
          Revision No.Details of ChangesReason for ChangeEffective Date
          00New SOPNot Applicable 

          Annexure-I

          DIFFERENT UNITS OF TESTS APPLIED IN QUALITY CONTROL

          REPORTING OF ANALYTICAL VALUES AND ROUNDING OFF THE DIGITS

          Click the link to download word file copy of this document:
          https://pharmaguidehub.com/product/reporting-of-analytical-values-and-rounding-off-the-digits/

          Share this article
          Shareable URL
          Prev Post

          CODIFICATION OF FIRE HOOTER AND SMOKE DETECTOR IN PHARMACEUTICAL

          Next Post

          PREPARATION OF TEST SOLUTIONS, INDICATOR SOLUTIONS AND LIMIT TEST STANDARD SOLUTIONS

          Leave a Reply

          Your email address will not be published. Required fields are marked *

          Read next

          CLEANING OF VACUUM OVEN

          To lay down the procedure for cleaning of vacuum oven. This SOP is applicable for the cleaning of vacuum oven at…

          Discover more from PharmaGuideHub

          Subscribe now to keep reading and get access to the full archive.

          Continue reading