PREPARATION OF TEST SOLUTIONS, INDICATOR SOLUTIONS AND LIMIT TEST STANDARD SOLUTIONS

PREPARATION OF TEST SOLUTIONS, INDICATOR SOLUTIONS AND LIMIT TEST STANDARD SOLUTIONS
PREPARATION OF TEST SOLUTIONS, INDICATOR SOLUTIONS AND LIMIT TEST STANDARD SOLUTIONS

OBJECTIVE:

To describe the procedure for Preparation of test solutions, indicator solutions and limit test standard solutions.

SCOPE:

This SOP is applicable to procedure for Preparation of test solutions, indicator solutions and limit test standard solutions.

RESPONSIBILITY:

  • Executive/Designee Quality Control: responsible to prepare the test solutions, indicator solutions and limit test standard solution.
  • Head QC: responsible for ensuring the compliance of SOP.

ACCOUNTABILITY:

QA Head shall be Accountable for implementation of SOP.

ABOUT TEST SOLUTIONS, INDICATOR SOLUTIONS AND LIMIT TEST STANDARD SOLUTIONS

In pharmaceutical analysis, test solutions are reagents prepared for specific analytical procedures to determine the quality, purity, or strength of a substance. They react with the sample under defined conditions, producing a measurable change. Indicator solutions are specialized test solutions that exhibit a distinct color change in response to a particular chemical condition, such as a change in pH during a titration or the presence of a specific ion, signaling the endpoint of a reaction. Limit test standard solutions, on the other hand, are accurately prepared solutions containing a known concentration of an impurity. These are crucial for limit tests, which are semi-quantitative methods used to ensure that the amount of a specified impurity in a pharmaceutical substance does not exceed an acceptable limit by comparing the reaction of the sample to that of the standard.

PROCEDURE:

 PREPARATION OF TEST SOLUTIONS:

For all preparations of test solutions use purified water and Analytical Grade chemicals.Prepare the solutions as per the procedures given in general test procedures.

Store the solutions in clean dry bottles at room temperature.

Note: Store light sensitive solutions in amber colour bottles

A reference number shall represent all test solutions. The solution prepared frequently shall bear an AR number.

Label the bottles as per the Format-I (Test solution label).

All test solutions should be used within 3 months from the date of preparation.

Fresh Test solution shall be prepared within 5 days on or before the ‘Valid Up to’ date.

PROCEDURE FOR ISSUANCE AND IN-HOUSE NUMBERING OF THE HPLC COLUMN:

A reference number shall represent each indicator solutions. Ex: For phenolphthalein indicator solution the reference number shall be QC/IS/01.

where QC is Department code

IS indicates indicator solution

and 01 is the reference number.

The solution prepared frequently shall bear an AR number. Eg: Phenolphthalein indicator solution initially shall have a number QC/IS/01/2801

where

QC is department code

IS is indicator solution

01 reference number

‘28’ represents the year

and ‘01’ represents the serial number which shall be a continuous number i.e.., 02, 03,…and so on.

Label the indicator solutions as per the Format-II (Label for indicator solution).

All indicator solutions should be used within 6 months from the date of preparation.

Ready to use indicators does not require any preparation. They shall be used directly after checking the sensitivity given in general test procedures. These solutions should be used within 12 months from the date opened.

PROCEDURE FOR LIMIT TEST STANDARD SOLUTIONS:

Follow the procedure described in test solutions.

Proportionately smaller or larger quantities of chemicals shall be weighed accurately, provided the measurement is made with at least equivalent accuracy and provide any subsequent steps, such as dilutions are adjusted to yield concentrations, equivalent to those intended solutions.

A reference number shall represent each Limit Test solution. Ex: For Lead standard solution the reference number shall be QC/LS/01

where

QC is Department code

LS is limit test standard

and 01 is the reference number.

The solution prepared frequently shall bear an AR number. Ex: Lead standard solution initially shall have a number QC/LS/01/2801

Where

QC is Department code

LS is limit test standard

01 is the reference number

‘28’ represents the year

and ‘01’ represents the serial number which shall be a continuous number i.e., 02, 03…. And so on.

Label the solution as per the Format-III (Label for limit test standard solution)

Specify the Concentration of the solution on the label.

All limit test standard solutions should be used within three months from the date of preparation.

Fresh Limit Test solutions shall be prepared within 5 days on or before the ‘Valid Up to’ date.

Click the link to download word file copy of this document:
https://pharmaguidehub.com/product/preparation-of-test-solutions-indicator-solutions-and-limit-test-standard-solutions/

REFERENCES:

Not Applicable

ANNEXURES:

ANNEXURE NO.TITLE OF ANNEXURE
Annexure-ILabel for test solution
Annexure-IILabel for indicator solution
Annexure-IIILabel for Limit Test solution
Annexure-IVPreparation record for Test solution, Indicator Solution and Limit Test Standard solution

ENCLOSURES: SOP Training Record.

DISTRIBUTION:

Master Copy                    :          Quality Assurance Department

Controlled Copy No. 01  :          Head Quality Assurance

Controlled Copy No. 02  :         Head Quality Control

ABBREVIATIONS:

No.:Number
COA:Certificate Of Analysis
SOP:Standard Operating Procedure
QC:Quality Control

REVISION HISTORY:             

CHANGE HISTORY LOG
Revision No.Details of ChangesReason for ChangeEffective Date
00New SOPNot ApplicableTo Be Written Manual

Annexure-I
LABEL FOR TEST SOLUTION

Annexure-II
LABEL FOR INDICATOR SOLUTION

Annexure-III
LABEL FOR LIMIT TEST SOLUTION

Annexure-IV
PREPARATION RECORD FOR TEST SOLUTION, INDICATOR SOLUTION AND LIMIT TEST STANDARD SOLUTION

Click the link to download word file copy of this document:
https://pharmaguidehub.com/product/preparation-of-test-solutions-indicator-solutions-and-limit-test-standard-solutions/

Share this article
Shareable URL
Prev Post

REPORTING OF ANALYTICAL VALUES AND ROUNDING OFF THE DIGITS

Next Post

OPERATION OF BOD INCUBATOR (Make: Newtronic)

Leave a Reply

Your email address will not be published. Required fields are marked *

Read next

Discover more from PharmaGuideHub

Subscribe now to keep reading and get access to the full archive.

Continue reading